1. How to caculate the flat style house area?
1)The length and the width are measured by " T ", 1T=1150mm; the height is measured by " H", 1H=1000mm,
So our standard flat house’s specification is nTxnTxnH(WxLxH).
1T=1150mm
1H=1000mm
Generally speaking, the width of our house is 3T~6T.
Length ≥3T.
Height=3,6H
One floor= 3H =3.00m, Two floors =6H=6m.
2).Area Calculation :
The area of a standard prefab house is calculated by the following rule:
① Area of house = (Exterior Wall Length+0.16m) ×( Exterior Wall Width+0.16m) × Storey amount.
0.16m is the width of C section steel column in two sides.
② Area of a standard stair is 4.5 sq.m per set.If need two sets,the total area of stair is 4.5x2=9 sq.m.
③ Area of awning is half of its projective area on level surface.
④ Area of balcony is its projective area on level surface.
⑤ Total Area =①+②+③+④
2.What is the service life of Yaoda Prefabricated Buildings ?
Prefabricated structures are in the long life building class and can be used safely about 50 years.Excessive wind, snow, rain, humitidy and the way of usage are the factors that can affect the structure’s life.It is needed to make maitenence as the other type of buildings need.
3.Can prefabricated buildings dissamble and reassemble in a differen locations ?
Yes, that's possible. It only requires disassembly cost, re-installation cost, painting cost, and sanitary installation cost. It is possible to make amendment in buildings if required.
4.Are Yaoda Prefabricated Buildings Resistant to Earthquakes Or Winds ?
Prefabricated buildings are resistent to 7.5 magnitude and 80 km/ h wind speed. Considering the weather and climate conditions of the place that the houses will build, we are able to deliver our prefabricated products to any place in the world.
5.What are the solutions in prefabricated buildings in cold regions ?
Exterior wall panels and roof can be modificate according to weather and climate conditions with TS 825 norms.
6.What are the area of usage of prefabricated buildings ?
Houses, villas, offices,social housing, social facilities,construction sites, cafeteria and dormitories, prefabricated factory and hangars
7.Does Container require a special care?
If followed the basic conditions of use no special care is required.
8.How is the container thermal and sound insulation achieved?
High level of thermal and sound insulation is provided thanks to Yaoda’s sandwich wall panels and 125mm roof panels. In comparison to other products of the same category Yaoda’s new generation containers are 60% more energy-saving. Yaoda’s new generation Containers are always winning.
9.How is the heating and cooling of the Container provided?
Our containers enjoy high level of thermal insulation. The inside temperature can be easily regulated by AC any other electrical device
flatpack containers can fit in one truck.